Global Switch – Madrid Technical Specification

Main Structural Features

  • Steel structure and pre-cast concrete panels, aluminium glazing to offices
  • Typical floor loading of 9kN/m². 20kN/m² in some specific areas
  • Slab to slab height of 3.70m
  • Raised floors with anti-static tiles with a height of between 600mm to 800mm. Clear height of between 3.20m - 2.80m
  • Column spacing: 9.84m

Redundant Power

  • N+N redundancy on power supply
  • Mains power supplied via 2 x 15kV incomers
  • Diverse A&B supply, distributed via 15kV main
  • Up to 1000 w/m² of power available on each floor
  • Backed up by 15kV diesel generators in N+1 configuration
  • On-site diesel tanks (2 x 50,000 litres) with 8 hour, 24x7 fuel delivery

Cooling and Environment

  • N+1 redundancy on cooling system
  • Temperature and humidity in technical space to industry accepted standards and maintained within energy efficient parameters
  • Hydraulic redundancy
  • Computer room air conditioning units (CRACs) in technical area backed up by 15kV diesel generators in N+1 configuration

Fire Detection and Suppression

  • Analogue fire detection system in all areas (smoke and heat) with manual break-glass units
  • VESDA early warning system
  • State of the art suppression systems in technical areas
  • Wet risers and hose reels to all floors from site dedicated fire pump room and tanks
  • CO² suppression systems in substation transformers

Building Management Systems

  • Dedicated 24x7 facilities management team
  • Full power monitoring system
  • Asset management system
  • BMS system monitors M&E operation within data centre to:
    - ensure stability of the environment
    - monitor key electrical and mechanical systems
    - enable interface between key systems
    - provide data gathering

Telecommunications

  • Carrier Neutral
  • Access to multiple telecommunications providers located within the data centre
  • Diverse cable entry points with a combination of 160mm and 32mm sub ducts
  • Basket trays to all data risers - fully access controlled
  • Multiple connection points to each area
  • Roof space availability for satellite and antennae equipment

Security

  • Premises Controllers manage data centre security 24x7
  • Access control using proximity card readers
  • Intruder alarms to all areas
  • Multiple CCTV cameras (interior and exterior)
  • Gate controlled vehicle access
  • Secure managed delivery and loading areas
  • Secure car park

Ancillary Services

  • Design and build services
  • Tailored private office areas to customer specification
  • Installation and cabling
  • Meeting rooms
  • On-site secure storage for deliveries
  • Technical cleaning